Hydraulic Power Unit

 

Description:

    The power unit uses a variable volume pump to conserve energy. An auxiliary pressure control on the cylinder manifold limits pressure to a safe level if the main pressure control fails. Filtration on the pump inlet is 79 microns. Filtration on the pump outlet is 3 microns. The filters are oversized to extend the time period between changes. Maximum water flow required is half pump flow with 85F water. Air-cooled power units are also available. Switches on the reservoir are used to shut the unit down in case of low oil level or overtemperature. The unit is supplied with motor starter unless otherwise specified by the customer.
 

SYSTEM SPECIFICATIONS

 
Line Speed l0-600 FPM
Cut-Off \Weights 10-15,000 lbs.
total time to accelerate and synchronize with material .03-.3 seconds
Accuracy + 1/32 inch